AB-3S-12 630-1250A 12KV Three-phase outdoor high voltage vacuum circuit breaker

We are a factory specializing in producing the AB-3S-12 630-1250A 12KV Three-phase outdoor high voltage vacuum circuit breaker. Get high-quality products now!

Request a Quote
  • AB-3S-12 630-1250A 12KV Three-phase outdoor high voltage vacuum circuit breaker
  • AB-3S-12 630-1250A 12KV Three-phase outdoor high voltage vacuum circuit breaker
  • AB-3S-12 630-1250A 12KV Three-phase outdoor high voltage vacuum circuit breaker
  • AB-3S-12 630-1250A 12KV Three-phase outdoor high voltage vacuum circuit breaker
  • AB-3S-12 630-1250A 12KV Three-phase outdoor high voltage vacuum circuit breaker
  • AB-3S-12 630-1250A 12KV Three-phase outdoor high voltage vacuum circuit breaker
  • AB-3S-12 630-1250A 12KV Three-phase outdoor high voltage vacuum circuit breaker
  • AB-3S-12 630-1250A 12KV Three-phase outdoor high voltage vacuum circuit breaker
  • AB-3S-12 630-1250A 12KV Three-phase outdoor high voltage vacuum circuit breaker
  • AB-3S-12 630-1250A 12KV Three-phase outdoor high voltage vacuum circuit breaker

PRODUCTS DETAILS

AB-3S-12 series circuit breaker is a new generation of intelligent vacuum circuit breaker on the column developed by our company, integrating advanced technology at home and abroad, taking advantage of the strength of many families, adopting a new design concept and using high -tech means. The product can be used as the switch of 10kV side and 10kV outlet of main transformer of 35kV substation, as well as the switch on the column of distribution network. It can easily realize control, protection, measurement and communication when combined with various control units produced by the company. It is the preferred equipment for realizing automation and miniaturization of distribution network.参数外形尺寸及安装 (6)外形尺寸及安装 (5)外形尺寸及安装 (2)外形尺寸及安装 (4)外形尺寸及安装 (3)1, magnetic (permanent magnet) mechanism, so that a large number of parts, closing power greatly reduced, stable and reliable, no regular maintenance. Ensure that the operation sequence of the reclosing device (t1-0.3s, t2-3s, t3 -3S, latching) is successfully completed; 2, using imported outdoor epoxy as external insulation material, light weight, long life, good weather resistance, no oil, no SF6, meet the requirements of environmental protection. 3, the advanced DSP chip, set control, protection, measurement, communication in the body, so that the system has advanced design, super function. 4, adopt integrated sensor technology to realize the on-line monitoring of the device; 5. Adopt synchronous closing technology to realize synchronous closing of circuit breaker and effectively suppress operating overvoltage and inrush current; 6, flexible communication mode, support general wireless packet service (GPRS), support Chinese and English short message; 7. Sampling up to 128 points per week and fast FFT transform provide high-speed and high-precision data from fundamental wave to 19th harmonic wave for line measurement and protection; 8, with fast protection function, make the distribution network in the absence of master station cooperation, also can automatically complete isolation and restore power supply, greatly improve the reliability of power supply; 9. Online judgment of single-phase grounding fault and warning or tripping can be realized without additional configuration; 10. Adopting temperature measurement and temperature correction technology, the device can achieve high accuracy under various temperature conditions; 11, specially designed power management module can provide automatic conversion of 2 auxiliary power input lines (AC1 10V or AC220V), monitor the battery and control the battery charging voltage and charge and discharge power; 12, friendly interface, full Chinese display, easy to set up; 13, all stainless steel manufacturing, no rust, really maintenance free.1. Ambient air temperature: -5~+40 and the average temperature should not exceed +35 in 24h. 2. Install and use indoors. Altitude above sea level for operation site should not exceed 2000M. 3. Relative humidity should not exceed 50% at max temperature +40. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20. But in view of the temperature change, it is possible that moderate dews will produce casually. 4. Installation gradient not exceed 5. 5. Install in the places without fierce vibration and shock and the sites insufficient to erode the electrical components. 6. Any specific requirement, consult with manufactory.

Hot Products

KLMG  64-136mm  Crossing road busbar transition fittings  Substation fitting

KLMG 64-136mm Crossing road busbar transition fittings Substation fitting

KYN61 40.5KV 1250A 1600A 2000A Armoured Removable High Voltage Switchgear HV Complete Set

KYN61 40.5KV 1250A 1600A 2000A Armoured Removable High Voltage Switchgear HV Complete Set

JH 16-240mm² 4.8-22.5mm H-type parallel groove wire clamp branch type cable crimping wire clamp

JH 16-240mm² 4.8-22.5mm H-type parallel groove wire clamp branch type cable crimping wire clamp

YJLV22 0.6/1KV 2-5 cores 16-400mm² Armored buried aluminum core power cable

YJLV22 0.6/1KV 2-5 cores 16-400mm² Armored buried aluminum core power cable

DT2   10-500mm²  8.4-17mm  Double hole type Copper galvanized connecting wire terminal cable lugs

DT2 10-500mm² 8.4-17mm Double hole type Copper galvanized connecting wire terminal cable lugs

XGN66 3.6KV 7.2KV 12KV 630A 1250A Fixed box type high voltage switchgear control equipment

XGN66 3.6KV 7.2KV 12KV 630A 1250A Fixed box type high voltage switchgear control equipment

ZR-YJV 8.7/35KV 25-1200mm² 1-3 core  Medium and high voltage flame retardant cross-linked copper core power cable

ZR-YJV 8.7/35KV 25-1200mm² 1-3 core Medium and high voltage flame retardant cross-linked copper core power cable

JZF4/FJQ  series  23-400mm²   330KV and above  Electric Power fitting Spacer dampers for anti jumper of overhead line

JZF4/FJQ series 23-400mm² 330KV and above Electric Power fitting Spacer dampers for anti jumper of overhead line

MGZ  45-250mm  Dead-end caps (Damper type) Electric power fittings Substation fitting

MGZ 45-250mm Dead-end caps (Damper type) Electric power fittings Substation fitting

YBW-12 11KV 15KV 33KV  400-2500KVA Outdoor European prefabricated substation

YBW-12 11KV 15KV 33KV 400-2500KVA Outdoor European prefabricated substation

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours