BHD2 series 200-400A 660/1140V Mine explosion-proof low-voltage cable junction box

BHD2 series 200-400A Mine explosion-proof low-voltage cable junction box. We are a factory specialized in manufacturing high-quality electrical products.

Request a Quote
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box
  • BHD2 series  200-400A  660/1140V  Mine explosion-proof low-voltage cable junction box

PRODUCTS DETAILS

BHD series mine explosion-proof low-voltage cable junction box is suitable for mines containing explosive dangerous gas (methane) and coal dust. In the power supply system of 1140V (200-400A), the common signal, lighting, power equipment, etc. are used for cable connection and branching.Mine explosion-proof low-voltage cable junction boxProduct features: 1. The junction box is mainly composed of flameproof shell (shell, cover) CM05, insulated terminal block, cable entry device, and internal and external grounding; 2. The shell and cover are made of flat flameproof surface through bolts and other fasteners Connection; 3. The terminal block is made of high-purity clay, which is pressed, sintered and glazed, and has excellent electrical insulation properties. Product use environment: 1. Ambient pressure 80KPa—106 Kpa 2. Ambient air temperature -20°C—+40°C 3. Air relative humidity not greater than 95% (+25°C) 4. No strong bumps and shocks Places 5. Places where there is no dripping water, rain and snow intrusion 6. Places where there is no corrosive gas and steam that can damage metals and insulation1. After the junction box is unpacked, it should be checked for damage and missing parts. 2. The junction box should be hung vertically on the upper part of the roadway or fixed on a special bracket. 3. The cables at the lead-in ends on both sides should have an appropriate amount of slack, and the cable heads should not be loaded. 4. After the two sides of the cable enter the box, the stress cone at the end of the cable needs to be fixed with a pallet. 5. The bare 30mm core wire at both ends of the cable is pressed with a special compression nut to the terminal (operated with a special wrench) to ensure reliable contact, and the core wire is not allowed to be loose. 6. The fastening bolts of all parts of the junction box must be complete and checked regularly by special personnel. If there is any problem, it must be dealt with in time. 7. The maintenance and relocation of the junction box must not be carried out under the condition of live electricity. The cover must be opened after the power supply is cut off and discharged by reliable means according to the requirements of the "Coal Mine Security Regulations". 8. The junction box must be grounded reliably when in use. 9. Before prefabricating the cable terminal, the compression flange, sealing ring, retaining ring and connecting section must be sleeved into the cable, and the cable terminal must be processed according to the terminal production process of the high-voltage cable. 10. When no control wire is introduced, braid the monitoring shield wires at both ends together and connect them through auxiliary terminals. Weave the grounding wires at both ends together and connect them to their respective internal grounding devices.

Hot Products

HRW 12/24KV  High voltage composite drop fuse drop switch with arc chute

HRW 12/24KV High voltage composite drop fuse drop switch with arc chute

SBT  12-20mm  Electric power fittings and equipment terminal clamp  Copper transformer wire clip

SBT 12-20mm Electric power fittings and equipment terminal clamp Copper transformer wire clip

GCK  380-660V  630-3150A  Low voltage draw out switch cabinet for mining  power distribution cabinet

GCK 380-660V 630-3150A Low voltage draw out switch cabinet for mining power distribution cabinet

RSG 0.6/1KV 1.0-150mm copper row bushing yellow and green two-color ground wire marking tube insulation flame retardant heat shrinkable tube

RSG 0.6/1KV 1.0-150mm copper row bushing yellow and green two-color ground wire marking tube insulation flame retardant heat shrinkable tube

FQBN/FQX series 25KV high voltage composite insulator for electrified railway tunnel

FQBN/FQX series 25KV high voltage composite insulator for electrified railway tunnel

BAM 10.5/11/12/11√3/12√3KV 200-500kvar Outdoor  Collective High Voltage Shunt Power Capacitors

BAM 10.5/11/12/11√3/12√3KV 200-500kvar Outdoor Collective High Voltage Shunt Power Capacitors

SY 0.6/1KV 2-5 Cores 10-400mm² Low Voltage Heat Shrinkable Cable Termination Cable Accessories

SY 0.6/1KV 2-5 Cores 10-400mm² Low Voltage Heat Shrinkable Cable Termination Cable Accessories

LZZBJ9-10  3/6/10KV  200-2000A High-quality HV current transformers for indoor switch cabinets

LZZBJ9-10 3/6/10KV 200-2000A High-quality HV current transformers for indoor switch cabinets

NXL 35-240mm² 14.5-36.4KN Wedge Insulation Self-locking Tension Clamp

NXL 35-240mm² 14.5-36.4KN Wedge Insulation Self-locking Tension Clamp

EV/EVVR   450/750/1000V   10-300A    Multi-core new energy electric vehicle charging pile connection cable

EV/EVVR 450/750/1000V 10-300A Multi-core new energy electric vehicle charging pile connection cable

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours