FDJ 16-300mm² 1KV Low Voltage Distribution Line protection against reverse electricity and Full Insulation Protective Grounding Device

Choose our FDJ 16-300mm² 1KV Low Voltage Distribution Line protection to safeguard against reverse electricity. We are a factory specialized in full insulation protective grounding devices.

Request a Quote
  • FDJ 16-300mm² 1KV Low Voltage Distribution Line protection against reverse electricity and Full Insulation Protective Grounding Device
  • FDJ 16-300mm² 1KV Low Voltage Distribution Line protection against reverse electricity and Full Insulation Protective Grounding Device
  • FDJ 16-300mm² 1KV Low Voltage Distribution Line protection against reverse electricity and Full Insulation Protective Grounding Device
  • FDJ 16-300mm² 1KV Low Voltage Distribution Line protection against reverse electricity and Full Insulation Protective Grounding Device
  • FDJ 16-300mm² 1KV Low Voltage Distribution Line protection against reverse electricity and Full Insulation Protective Grounding Device
  • FDJ 16-300mm² 1KV Low Voltage Distribution Line protection against reverse electricity and Full Insulation Protective Grounding Device
  • FDJ 16-300mm² 1KV Low Voltage Distribution Line protection against reverse electricity and Full Insulation Protective Grounding Device
  • FDJ 16-300mm² 1KV Low Voltage Distribution Line protection against reverse electricity and Full Insulation Protective Grounding Device
  • FDJ 16-300mm² 1KV Low Voltage Distribution Line protection against reverse electricity and Full Insulation Protective Grounding Device

PRODUCTS DETAILS

The anti-power-down protection device is suitable for low-voltage insulated distribution lines of 1KV and below on both sides of the tie switch, at the joints of branch poles and tension poles, and at the branch line points that may be reversed (or the branch line with a three-phase power meter installed) The grounding protection of the grounding point of the power failure should be set on the wire of the power failure.参数 形象5characteristic: 1. Keep the line in an insulated state and eliminate the hidden danger of electric shock 2. Easy to install, open the button to connect the ground wire directly 3. The combination of wire protection copper foil and insulating tape greatly enhances the anti-oxidation performance of the conductor and improves the life of the cable 4. Double protection, that is to prevent water vapor or air from entering the interface, and ensure the insulation effect when the interface is not in use 5. It can be reused and has the same life as the wire. It is an energy-saving and environmentally friendly product. 6. Stable product performance, maintenance-free, maintenance-free, greatly reducing maintenance costs Install: 1. Strip the wire insulation about 70-75mm, 2. Wrap tinned copper foil to protect the cable conductors, 3. Wrap 5-8 layers of electrical tape around the ends of the two insulating layers, 4. Cut the length of the waterproof sealing tape according to the installed wire section, wrap both ends, 5. Install the anti-shock insulating protective cover, fasten the buckles one by one, 6. Product installation completion diagram,1. Altitude: ≤ 1000M 2. Ambient temperature: -25℃~+50℃ 3. Sunlight intensity: up to 0.1W/cm2 (wind speed: 0.5m/s) 4. Maximum temperature difference: 25K 5. Maximum wind speed: 35m/s 6. Ice thickness: ≤ 10mm 7. Earthquake resistance: ≤ class 8 8. Installation location: outdoor

Hot Products

MRJ  120-400mm²  19-33mm  Spacers for double bus-bar conductor  Electric power protective fitting

MRJ 120-400mm² 19-33mm Spacers for double bus-bar conductor Electric power protective fitting

SCK 35-300mm² 7.5-22.4mm Electrical Equipment Outlet Connection Clamp C-Type Temperature Measuring Clamp

SCK 35-300mm² 7.5-22.4mm Electrical Equipment Outlet Connection Clamp C-Type Temperature Measuring Clamp

FPQ 10/35KV Outdoor High Voltage Composite Silicone Rubber Needle Lightning Insulator

FPQ 10/35KV Outdoor High Voltage Composite Silicone Rubber Needle Lightning Insulator

DTF  25-500mm²  11-17mm   Water-proof connecting terminal Tinned copper cable lugs

DTF 25-500mm² 11-17mm Water-proof connecting terminal Tinned copper cable lugs

NLS/WLS/JLS 26/35KV 1/3 Core Indoor and Outdoor Silicone Rubber Cold Shrink Cable Termination, Intermediate joint

NLS/WLS/JLS 26/35KV 1/3 Core Indoor and Outdoor Silicone Rubber Cold Shrink Cable Termination, Intermediate joint

GW9 12KV Low price direct sale outdoor high voltage isolating switch

GW9 12KV Low price direct sale outdoor high voltage isolating switch

XRNM 6KV 12KV   50KA Best selling  High voltage current limiting fuses for motor protection     British BS Standards

XRNM 6KV 12KV 50KA Best selling High voltage current limiting fuses for motor protection British BS Standards

KYN28 24KV 630A 2000A 4000A Armoured removable AC enclosed switchgear

KYN28 24KV 630A 2000A 4000A Armoured removable AC enclosed switchgear

JLSZW-10W 10-400/500-600/800-1000A 10/15VA Outdoor Dry Combination Transformer High Voltage Metering Box

JLSZW-10W 10-400/500-600/800-1000A 10/15VA Outdoor Dry Combination Transformer High Voltage Metering Box

YJV22  0.6/1KV  10-400mm² 2-5 core Low and medium voltage armored pure copper cross-linked power cable

YJV22 0.6/1KV 10-400mm² 2-5 core Low and medium voltage armored pure copper cross-linked power cable

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours