KCGGD 380V 500V 100-2000KW three phase photovoltaic grid-connected metering cabinet

Shop our factory-made KCGGD three phase photovoltaic grid-connected metering cabinet. Browse our collection of reliable, energy-efficient solutions for solar power integration. Order now!

Request a Quote
  • KCGGD 380V 500V 100-2000KW  three phase photovoltaic grid-connected metering cabinet
  • KCGGD 380V 500V 100-2000KW  three phase photovoltaic grid-connected metering cabinet
  • KCGGD 380V 500V 100-2000KW  three phase photovoltaic grid-connected metering cabinet
  • KCGGD 380V 500V 100-2000KW  three phase photovoltaic grid-connected metering cabinet
  • KCGGD 380V 500V 100-2000KW  three phase photovoltaic grid-connected metering cabinet
  • KCGGD 380V 500V 100-2000KW  three phase photovoltaic grid-connected metering cabinet
  • KCGGD 380V 500V 100-2000KW  three phase photovoltaic grid-connected metering cabinet

PRODUCTS DETAILS

This product is mainly used in 100KW~2000KW high-power industrial and commercial photovoltaic grid-connected power generation systems, and is connected in series between the grid-connected inverter (or AC combiner box) and the power grid. , power grid low voltage, power grid overvoltage, input lightning protection, system overcurrent, power grid isolation and a series of protection, multi-function meter display and fault status indication make the system operating status clear at a glance, the product has passed the industry standard CCC certification, CE certification, ISO9001 quality management System certification, etc.
Product model KCGGD
Installed power 100-2000KW
The number of inverter input channels 1 way~5way(The above suggested matching AC combiner box)
Grid-connected output channels 1way
Grid connection requirements Three-phase grid-connected cabinet
Grid-connected voltage AC:380V~AC:500V
Protective function:  
Short circuit protection Have
Overload protection Have
Lightning protection Have (nominal current: In: 20KA, Imax: 40KA, Up≤4KV)
Isolation Protection (Visual Breakpoints) Have(knife switch/disconnector)
Optional function 1. Online power quality monitor 2. Anti-islanding protection device 3. Accident Degradation Column Device
Panel manual opening and closing Have
Overvoltage and undervoltage protection Have
Automatic reclosing Have
Grid-connected switch:    
Plastic case reclosing 100~800A (optional) 1. When the power grid is powered off or the bias voltage is greater than 20%, it will automatically trip (0~10S delayed tripping time is adjustable) 2. When the power grid returns to normal, it will automatically close 3. Manual operation and automatic operation can be switched 4. Phase loss protection, zero break protection 5. Check for pressure closing
Universal frame circuit breaker 200~4000A (optional)
Applicable environment:    
Temperature, humidity Working temperature: -25 to +60 °C Storage temperature: -40 to +70 °C, humidity: 0-90% no condensation; no corrosive gas place (if any, please specify)
Use altitude ≤3000M
Salt spray resistant Standard salt spray test 336 hours
General parameters:
Box material Cold-rolled plate spraying, stainless steel
Use place Indoor type (can be customized outdoor type)
Type of cabinet Power distribution cabinet, metering cabinet, transformer cabinet, isolation switch cabinet
Installation method Floor standing installation
Box size (D*W*H) 600mm*800mm*2200mm/800mm*800mm*2200mm(Customizable)
The installation location of the meter and collector is reserved, the view window of the meter, the lead seal (anti-theft), the integrated design concept of the product, the power distribution part and the metering part are completely isolated, the electromagnetic interference is reduced, and the photovoltaic special plastic case reclosing circuit breaker It can be equipped with on-line power quality monitoring, anti-islanding protection device, fault de-loading device, etc. Outdoor and indoor installations are optional, making installation more convenient. Support special requirements and function customization.1. Ambient air temperature: -5~+40 and the average temperature should not exceed +35 in 24h. 2. Install and use indoors. Altitude above sea level for operation site should not exceed 2000M. 3. Relative humidity should not exceed 50% at max temperature +40. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20. But in view of the temperature change, it is possible that moderate dews will produce casually. 4. Installation gradient not exceed 5. 5. Install in the places without fierce vibration and shock and the sites insufficient to erode the electrical components. 6. Any specific requirement, consult with manufactory.

Hot Products

XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers

XRNT 6KV 12KV 20KV 24KV 35KV 40.5KV 50KA High voltage current limiting fuses for protection of transformers

JSZJK-10Q 3000√3/100√3 /100V 60-100VA Indoor Dry Type Anti-Resonance Three-phase Voltage Transformer

JSZJK-10Q 3000√3/100√3 /100V 60-100VA Indoor Dry Type Anti-Resonance Three-phase Voltage Transformer

DTG  4-1000mm²  4.2-23mm Tube Pressed Copper connecting Terminal  Tinned Copper Cable Lug

DTG 4-1000mm² 4.2-23mm Tube Pressed Copper connecting Terminal Tinned Copper Cable Lug

JGH 76-165mm 120*150*60mm  High voltage cable fixing wire clamp Single core aluminum alloy cable clamp

JGH 76-165mm 120*150*60mm High voltage cable fixing wire clamp Single core aluminum alloy cable clamp

DL  16-800mm² 8.4-21mm  Aluminium Connecting Terminal   Cable Lug  Electric power fitting

DL 16-800mm² 8.4-21mm Aluminium Connecting Terminal Cable Lug Electric power fitting

FNB4 1-35KV composite tensile insulator for high voltage transmission lines

FNB4 1-35KV composite tensile insulator for high voltage transmission lines

ZW32-40.5KV 630-1250A outdoor permanent magnet high voltage vacuum circuit breaker

ZW32-40.5KV 630-1250A outdoor permanent magnet high voltage vacuum circuit breaker

SF(Z)11 series  60KV  6300-63000KVA   Three phase air-cooled on load (non excitation) oil immersed voltage regulating power transformer

SF(Z)11 series 60KV 6300-63000KVA Three phase air-cooled on load (non excitation) oil immersed voltage regulating power transformer

FD2 6.3/10/11√3KV 1.7-3.4Mvar outdoor high voltage parallel capacitor special discharge coil

FD2 6.3/10/11√3KV 1.7-3.4Mvar outdoor high voltage parallel capacitor special discharge coil

LXK-80/100/120 aperture 10/35KV indoor HV zero-sequence current transformer opening and closing type through-core protection transformer

LXK-80/100/120 aperture 10/35KV indoor HV zero-sequence current transformer opening and closing type through-core protection transformer

Contact us