KCJXF 220V 380V 3-200KW single-phase three-phase photovoltaic grid-connected distribution box

As a factory, we offer the KCJXF grid-connected distribution box with options of 220V/380V and 3-200KW for single-phase or three-phase photovoltaic systems.

Request a Quote
  • KCJXF  220V 380V 3-200KW  single-phase three-phase photovoltaic grid-connected distribution box
  • KCJXF  220V 380V 3-200KW  single-phase three-phase photovoltaic grid-connected distribution box
  • KCJXF  220V 380V 3-200KW  single-phase three-phase photovoltaic grid-connected distribution box
  • KCJXF  220V 380V 3-200KW  single-phase three-phase photovoltaic grid-connected distribution box
  • KCJXF  220V 380V 3-200KW  single-phase three-phase photovoltaic grid-connected distribution box
  • KCJXF  220V 380V 3-200KW  single-phase three-phase photovoltaic grid-connected distribution box

PRODUCTS DETAILS

Our company's PV array lightning protection combiner box is designed to meet this requirement and can be designed to a complete PV power generation system solution with PV inverter products. Using PV combiner box, the user can put certain number of same specifications PV modules into series PV module according to input DC voltage range of the inverter, and then a number of series PV modules access to the PV array lightning protection box.It's convenient to facilitate the post-inverter through the output for lightning protection device and circuit breaker.(1) meet the requirements of outdoor installation, protection class IP65, with anti-UV, anti-acid, anti-alkali, moisture, mildew, rodent control and other functions; (2) access PV array, each with 15A, 1000Vdc fuse (replaceable other grades); (3) Equipped with special high-voltage lightning protection device, lightning protection function with cathode and anode ; (4) Positive, negative string into the fuse; (5) Use quadruple PV dedicated circuit breaker with positive and negative in series;1. Ambient air temperature: -5~+40 and the average temperature should not exceed +35 in 24h. 2. Install and use indoors. Altitude above sea level for operation site should not exceed 2000M. 3. Relative humidity should not exceed 50% at max temperature +40. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20. But in view of the temperature change, it is possible that moderate dews will produce casually. 4. Installation gradient not exceed 5. 5. Install in the places without fierce vibration and shock and the sites insufficient to erode the electrical components. 6. Any specific requirement, consult with manufactory.
Product model KCJXF (single phase) KCJXF (three-phase)
Installed power 3KW-20KW 3KW-200KW
The number of inverter input channels 1 way/2way/3way/4way(It is recommended to use a combiner box as above)
Grid-connected output channels 1 way
Grid connection requirements Single-phase/three-phase grid connection
Grid-connected voltage AC:220                AC:380
Switching capacity 20A-100A 32A-400A
Protective function: Have
Short circuit protection Have
Overload protection Have(Nominal current: In: 20KA, Imax: 40KA, Up≤4KV)
Isolation Protection (Visual Breakpoints) Have(knife switch/hand-pull disconnector)
Overvoltage and undervoltage protection Have
Automatic reclosing Have
Grid-connected switch:    
Self-resetting overvoltage and undervoltage protector (optional) 40A~125A 1. When the power grid is powered off or the bias voltage is greater than 20%, it will automatically disconnect (internal disconnection); 2. When the power grid returns to normal, it will automatically pull in (internally connected)
Photovoltaic special small reclosing circuit breaker (optional) 20A~100A 1. When the power grid is powered off or the bias voltage is greater than 20%, it will automatically open (operating handle action); 2. When the power grid returns to normal, it will automatically close (operating handle action) 3. Manual operation and automatic operation can be switched 4. Check the voltage closing
Plastic case recloser (optional) 40A~400A 1. When the power grid is powered off or the bias voltage is greater than 20%, it will automatically trip (the delayed tripping time is adjustable from 0-10S); 2. When the power grid returns to normal, it will automatically close 3. Manual operation and automatic operation can be switched 4. Check the voltage closing 5. Phase loss protection, zero-break protection
Applicable environment:    
Temperature, humidity Working temperature: -25 to +60 °C Storage temperature: -40 to +70 °C, humidity: 0-90% no condensation; no corrosive gas place (if any, please specify)
Use altitude ≤3000M
Salt spray resistant Standard salt spray test 336 hours
General parameters:    
Box material Stainless steel, cold-rolled plate spray, stainless steel spray, glass fiber reinforced plastic (SMC), transparent plastic box
Protection class Outdoor IP45/IP55/IP65
Box type Double door with meter (power distribution bin, metering bin) single door without measuring bin (optional)
Installation method Wall-mounted
Box size (L*W*H) Customized on demand

Hot Products

DTL 8.4-21mm Copper-aluminum transition terminal  clamp cable lug

DTL 8.4-21mm Copper-aluminum transition terminal clamp cable lug

TJ 16-240mm² Copper Bolt Connection wire Clamp Split type Bolt Connector

TJ 16-240mm² Copper Bolt Connection wire Clamp Split type Bolt Connector

YJLV 0.6/1KV 10-400mm² 1-5 cores High quality cross-linked aluminum core power cable

YJLV 0.6/1KV 10-400mm² 1-5 cores High quality cross-linked aluminum core power cable

JDJ2 35KV 35000/100V 0.2/6P 80-500VA Outdoor HV Oil-immersed Insulation Voltage Transformer

JDJ2 35KV 35000/100V 0.2/6P 80-500VA Outdoor HV Oil-immersed Insulation Voltage Transformer

ZN85-40.5KV 1250-2000A three-phase AC indoor high voltage vacuum circuit breaker

ZN85-40.5KV 1250-2000A three-phase AC indoor high voltage vacuum circuit breaker

XGN66 3.6KV 7.2KV 12KV 630A 1250A Fixed box type high voltage switchgear control equipment

XGN66 3.6KV 7.2KV 12KV 630A 1250A Fixed box type high voltage switchgear control equipment

CEF(CVV)/DA  series 0.6/1KV    EPR(PVC、NR+SBR) Insulated power cables for ships and Marine construction

CEF(CVV)/DA series 0.6/1KV EPR(PVC、NR+SBR) Insulated power cables for ships and Marine construction

EV/EVVR   450/750/1000V   10-300A    Multi-core new energy electric vehicle charging pile connection cable

EV/EVVR 450/750/1000V 10-300A Multi-core new energy electric vehicle charging pile connection cable

JDZ9  3/6/10KV 30-500VA Dry-type fully enclosed single-phase indoor HV voltage transformer

JDZ9 3/6/10KV 30-500VA Dry-type fully enclosed single-phase indoor HV voltage transformer

DSQ/SSQ/ZT 10/35KV 1-5 Cores 10-500mm² Heat Shrink Cable Rain Skirt and Heat Shrink Cable Finger Cover Cable Termination Accessories

DSQ/SSQ/ZT 10/35KV 1-5 Cores 10-500mm² Heat Shrink Cable Rain Skirt and Heat Shrink Cable Finger Cover Cable Termination Accessories

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours