KW(JJC) series 1-20KV 0.75-400mm² Insulated puncture type cable connector

Shop the KW(JJC) series puncture type cable connector at our factory. Insulated for safety, available in various sizes (1-20KV, 0.75-400mm²). Browse now! #factory #cableconnectors #insulated

Request a Quote
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector
  • KW(JJC) series  1-20KV   0.75-400mm²  Insulated puncture type cable connector

PRODUCTS DETAILS

The insulation puncture clamp (connector) is mainly composed of an insulation shell, a puncture blade, a waterproof rubber pad, and a torque bolt. When making a cable branch connection, insert the branch cable into the branch cap and determine the branch position of the main line, then use a socket wrench to tighten the torque nut on the clamp. With the tightening of the torque nut, the upper and lower parts of the clamp have hidden insulators with piercing blades At the same time, the arc-shaped sealing rubber pad wrapped around the piercing blade is gradually clinging to the cable insulation layer, and the piercing blade also begins to pierce the cable insulation layer and metal conductor. When the sealing degree of the sealing rubber pad and insulating grease and the contact between the puncture blade and the metal body reach the best effect, the torque nut will automatically fall off, at this time, the installation is completed and the contact point sealing and electrical effect reach the best. Insulation piercing clamps can be divided into 1KV, 10KV, and 20KV insulation piercing clamps according to voltage classification. According to the functional classification, it can be divided into ordinary insulation piercing wire clips, electrical inspection grounding insulation piercing wire clips, lightning protection and arc proof insulation piercing wire clips, and fireproof insulation piercing wire clips参数 参数1 参数KW150 结构1安装效果图 形象4_看图王Structural features: 1. Puncture structure, simple installation, no need to peel the insulated wire; 2. Torque nut, constant puncture pressure, ensure good electrical connection without damaging the wire, 3. Self sealing structure, moisture-proof, water-proof and anti-corrosion, extending the service life of insulated conductors and clamps 4. Special contact blade is used for copper (aluminum) butt joint and copper aluminum transition 5. The electrical contact resistance is small, and it is less than 1.1 times of the resistance of equal length branch conductor, meeting the DL/T765.1-2001 standard 6. Special insulating shell, anti light and environmental aging, dielectric strength>12KV 7. Curved surface design, applicable to the connection of the same (reducing) diameter conductor, with a wide connection range (0.75mm2-400mm2) Product advantages: 1. Simple installation: cable branch can be made without stripping the insulation skin of the cable, and the joint is completely insulated. It is not necessary to cut off the main cable, and branches can be made at any position of the cable. The installation is simple and reliable. It can be installed with electricity only by using a socket wrench. 2. Safety in use: the connector is resistant to twisting, shockproof, waterproof, flame retardant, and electrochemical corrosion aging, requiring no maintenance. It has been successfully used for more than 30 years. 3. Cost saving: the installation space is very small, saving the cable tray and civil engineering costs. For application in buildings, there is no need for terminal box, distribution box, cable return, and cable investment. The cost of cable+piercing clamp is lower than that of other power supply systems, which is only about 40% of the plug-in bus and about 60% of the prefabricated branch cable.1. Adjust the nut of the piercing clamp to the proper position, and insert the branch wire into the branch wire cap completely. 2. Insert the main line. If the main line has two layers of insulation, a certain length of outer insulation must be stripped at the connection position. 3. Put the main/branch line in a proper position and keep them parallel. First, tighten the nut by hand to fix the clamp. 4. Tighten the nut evenly with a socket wrench of the corresponding size until the top breaks off and the installation is complete. Installation of the double-screw insulation piercing clamp: 1. Unscrew the clamp first and snap the main wire into the main wire groove. Do not jam the main wire and the knife ruler crookedly. Pay attention to whether the wire diameter range corresponds to this wire clip. 2. Put the branch line into the branch line slot. The precautions are the same as above. 3. Tighten with a socket wrench. Open-end wrenches are disabled. 4. Note that the two nuts should be screwed down synchronously in sequence. 5. When tightened to a certain strength, the constant torque nut is twisted off. The installation is complete.

Hot Products

FDJ 16-300mm² 1KV Low Voltage Distribution Line protection against reverse electricity and Full Insulation Protective Grounding Device

FDJ 16-300mm² 1KV Low Voltage Distribution Line protection against reverse electricity and Full Insulation Protective Grounding Device

BV  10/16/25mm² 450/750V  Oxygen Free Copper PVC Insulated Copper Core Hard Wire

BV 10/16/25mm² 450/750V Oxygen Free Copper PVC Insulated Copper Core Hard Wire

CPTAU  0.6/1KV  20-30.5mm  Pre-insulated copper-aluminum Cable  lugs

CPTAU 0.6/1KV 20-30.5mm Pre-insulated copper-aluminum Cable lugs

SL  12-48 cores Power fittings  ADSS/OPGW optical fiber cable joint box

SL 12-48 cores Power fittings ADSS/OPGW optical fiber cable joint box

JGW 40-165mm 1-3 core  High voltage cable fixing clamp Cable hoop

JGW 40-165mm 1-3 core High voltage cable fixing clamp Cable hoop

XGH  5.1-28mm  Suspension clamp (Envolope type) Electric power fittings

XGH 5.1-28mm Suspension clamp (Envolope type) Electric power fittings

GGD  600A 1000A 2000A Indoor low-voltage fixed switchgear made in China 380V

GGD 600A 1000A 2000A Indoor low-voltage fixed switchgear made in China 380V

HXGN15 12KV 630A  Ring network cabinet Electrical control cabinet Switch control cabinet

HXGN15 12KV 630A Ring network cabinet Electrical control cabinet Switch control cabinet

MGZ  45-250mm  Dead-end caps (Damper type) Electric power fittings Substation fitting

MGZ 45-250mm Dead-end caps (Damper type) Electric power fittings Substation fitting

UB/PS/PD/P  series  20-50mm  70-600KN  Overhead Electric Power line link fitting  clevis

UB/PS/PD/P series 20-50mm 70-600KN Overhead Electric Power line link fitting clevis

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours