MY/MYP 0.38/0.66/1.14KV 4-400mm2 Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine

Buy quality mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine from our factory. Rated at 0.38/0.66/1.14KV, available in 4-400mm2.

Request a Quote
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine
  • MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine

PRODUCTS DETAILS

This product is a series of mining rubber sheathed flexible cables. Applicable to: mobile coal shearing units and other equipment with rated voltage of 0.66/1.14KV and below are used for connecting power lines. MY-0.38/0.66 Coal Mine Mobile Rubber Sheathed Flexible Cable Rated Voltage 0.38/0.66KV Power Connection of Various Underground Mobile Coal Mining Equipment MYE-0.38/0.66 Coal Mine Mobile Elastomer Flexible Cable Rated Voltage 0.38/0.66KV Power supply connection for underground mobile coal mining equipment MYP-0.38/0.66 mobile shielded rubber sheathed flexible cable for coal mines Rated voltage is 0.38/0.66KV Power supply connection for various underground mobile coal mining equipment MYPE-0.38/0.66 mobile shielding elastomer soft The rated voltage of the cable is 0.38/0.66KV The power supply connection of various underground mobile coal mining equipment MYP-0.66/1.14 coal mine mobile shielded rubber sheathed flexible cable The rated voltage is 0.66/1.44KV The power supply connection of various underground mobile coal mining equipment

Structural characteristics of rubber sheathed cable for mining: 1: The flexibility of conductor core shall be based on electric drill cable and excavator cable; The following measures shall be taken for conductor structure: 1. Softer copper single wire with fine diameter shall be used, bundled and twisted at small pitch. The bending torsion of the whole cable is also affected by the insulation and sheath structures, so it cannot be considered that the thinner the monofilament is, the smaller the pitch is, the better. 2. The flexibility can be improved by using the same direction stranding and multiple stranding. 3. In order to facilitate the relative sliding of wires in the insulating layer and facilitate the installation and maintenance. The monofilament of electric drill cable and cable conductor of small section excavator shall be tinned, and the cable of large section excavator shall be insulated with paper tape outside the conductor. 2: The insulation layer shall have sufficient electrical insulation performance 1. Use rubber with rubber content no less than 35% 2. The insulation thickness is thicker than that of general rubber sheathed cable 3. Rubber with good electrical property and good rubber extrusion process (such as continuous rubber extrusion and vulcanization production line) 3: MCP cable product introduction MCP shearer shield cable outer diameter dimension layer The semi conductive rubber shall be used as the layer, and its transition resistance shall meet the standard requirements to ensure the reliable action of the relay protection system in the event of an accident. 4: Cushion core The AC breakdown strength has a great relationship with the voltage rise speed. The cable breakdown caused by continuous voltage rise within a few minutes is called instantaneous breakdown. There is basically no thermal factor, and it belongs to the type of electrical breakdown. Therefore, wires and cables are generally not subject to such tests. The other is to step up the voltage step by step, starting from a lower voltage (such as 0.5~2 times of the working voltage), and maintaining sufficient working time to enable the cable to fully generate electricity and heat in this voltage level. Then rise to another voltage level. Rise step by step until breakdown. The rising voltage of each stage increases step by step according to the percentage of initial pressurization. This test reflects the factors of thermal breakdown. The test results are of good reference value. It is often used when researching product characteristics. 7: The cable shall be compact and compact in structure, and each element shall have relative sliding property. This product is a series of rubber sheathed flexible cables for mining. Applicable to: mobile coal mining unit and other equipment with rated voltage of 0.66/1.14KV and below are used to connect power lines. MY-0.38/0.66 Mobile rubber sheathed flexible cable for coal mine with rated voltage of 0.38/0.66KV Power connection of various underground mobile mining equipment MYE-0.38/0.66 Mobile elastomer flexible cable for coal mine with rated voltage of 0.38/0.66KV Power connection of various underground mobile mining equipment MYP-0.38/0.66 Mobile shielded rubber sheathed flexible cable for coal mine with rated voltage of 0.38/0.66KV Power connection of various underground mobile coal mining equipment MYPE-0.38/0.66 Mobile Shielded Elastomer Flexible Cable for Coal Mine with Rated Voltage of 0.38/0.66KV Power Connection of Various Underground Mobile Mining Equipment MYP-0.66/1.14 Mobile shielded rubber sheathed flexible cable for coal mine with rated voltage of 0.66/1.44KV Power connection of various underground mobile coal mining equipment Operating conditions: Rated voltage Uo/U is 0.38/0.66 and 0.66/1.14KV Long term working temperature of cable conductor is 65 ℃ The Z small bending radius of the cable is 6 times of the cable diamete

Matters needing attention: Common cable faults Common faults in cable lines include mechanical damage, insulation damage, insulation damp, insulation aging and deterioration, overvoltage, and cable overheating faults. When the above fault occurs in the line, the power supply of the faulty cable should be cut off, the fault point should be found, the fault should be checked and analyzed, and then repaired and tested. Safety requirements for buried cables 1. When the cables cross each other, the high-voltage cables should be under the low-voltage cables. If one of the cables is protected by pipes within 1m before and after the intersection or separated by partitions, the minimum allowable distance is 0.15m. 2. When the cable is close to or crossed with the heat pipe, if there are thermal insulation measures, the minimum distance between parallel and cross is 0.5m and 0.15m respectively. 3. When the cable crosses the railway or road, it should be protected by a pipe, and the protection pipe should extend beyond 2m from the track or road surface. 4. The distance between the cable and the foundation of the building should be able to ensure that the cable is buried outside the building's water; when the cable is introduced into the building, it should be protected by a pipe, and the protection pipe should also extend beyond the building's water. 5. The distance between the cables directly buried in the ground and the grounding of the general grounding device should be 0.15~0.5m; the buried depth of the cables directly buried in the ground should generally not be less than 0.7m, and should be buried under the frozen soil layer.参数01 参数02 参数03 结构 形象1_看图王

Hot Products

SY 0.6/1KV 2-5 Cores 10-400mm² Low Voltage Heat Shrinkable Cable Termination Cable Accessories

SY 0.6/1KV 2-5 Cores 10-400mm² Low Voltage Heat Shrinkable Cable Termination Cable Accessories

YH5WZ 35KV zinc oxide arrester for high voltage power station

YH5WZ 35KV zinc oxide arrester for high voltage power station

LCZ-35 50-1500A Indoor High Voltage Dry Current Transformer

LCZ-35 50-1500A Indoor High Voltage Dry Current Transformer

YH/YHF  200/400V  10-185mm²    High strength rubber sleeve electric welding cable

YH/YHF 200/400V 10-185mm² High strength rubber sleeve electric welding cable

BYD 35-240mm²  1-10KV  Overhead Insulated Power Line Electric-check Grounding Ring Device

BYD 35-240mm² 1-10KV Overhead Insulated Power Line Electric-check Grounding Ring Device

DSQ/SSQ/ZT 10/35KV 1-5 Cores 10-500mm² Heat Shrink Cable Rain Skirt and Heat Shrink Cable Finger Cover Cable Termination Accessories

DSQ/SSQ/ZT 10/35KV 1-5 Cores 10-500mm² Heat Shrink Cable Rain Skirt and Heat Shrink Cable Finger Cover Cable Termination Accessories

FZRN25-12D 12KV 630A Indoor high-voltage vacuum load switch and fuse combination electrical appliances

FZRN25-12D 12KV 630A Indoor high-voltage vacuum load switch and fuse combination electrical appliances

RW11 series 12KV 100/200A outdoor high voltage protection switch drop-out fuse

RW11 series 12KV 100/200A outdoor high voltage protection switch drop-out fuse

JH 16-240mm² 4.8-22.5mm H-type parallel groove wire clamp branch type cable crimping wire clamp

JH 16-240mm² 4.8-22.5mm H-type parallel groove wire clamp branch type cable crimping wire clamp

RVV  1/1.5/2.5  300/500V 2-5 Core  Flame retardant insulation sheathed soft copper core power cord

RVV 1/1.5/2.5 300/500V 2-5 Core Flame retardant insulation sheathed soft copper core power cord

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours