RW12 15/27KV 100/200A outdoor high voltage drop fuse switch for transmission line branch and transformer protection

Choose our high voltage drop fuse switch for efficient transmission line and transformer protection. We are a factory, ensuring top-quality products.

Request a Quote
  • RW12   15/27KV 100/200A outdoor high voltage drop fuse switch for transmission line branch and transformer protection
  • RW12   15/27KV 100/200A outdoor high voltage drop fuse switch for transmission line branch and transformer protection
  • RW12   15/27KV 100/200A outdoor high voltage drop fuse switch for transmission line branch and transformer protection
  • RW12   15/27KV 100/200A outdoor high voltage drop fuse switch for transmission line branch and transformer protection
  • RW12   15/27KV 100/200A outdoor high voltage drop fuse switch for transmission line branch and transformer protection
  • RW12   15/27KV 100/200A outdoor high voltage drop fuse switch for transmission line branch and transformer protection
  • RW12   15/27KV 100/200A outdoor high voltage drop fuse switch for transmission line branch and transformer protection
  • RW12   15/27KV 100/200A outdoor high voltage drop fuse switch for transmission line branch and transformer protection
  • RW12   15/27KV 100/200A outdoor high voltage drop fuse switch for transmission line branch and transformer protection

PRODUCTS DETAILS

RW12 series drop-out fuses are outdoor high-voltage protection appliances in power transmission and distribution systems. They are installed on the high-voltage side of distribution transformers or on branch lines of distribution lines, and are used for short-circuit and overload protection of transformers and lines, as well as split and combined load currents. The high-voltage ceramic drop-out fuse is composed of a ceramic insulating bracket and a fuse tube. The static contact is installed at both ends of the insulating bracket, and the moving contact is installed at both ends of the fuse tube. The fuse tube is composed of the inner arc suppression tube and the fuse tube. The outer layer is composed of phenolic paper tube or epoxy glass cloth tube. The load drop type fuse enhances the elastic auxiliary contact and arc extinguishing cover to divide and combine the load current.参数1 熔断器对应参数 安装尺寸 安装图 Bracket installation diagram:  安装尺寸1 Product installation effect: 安装Melt tube structure: Fuse take made of flberglsaa, damp-proof & corrosion-proof. Fuse base: Product base embedded mechanical structure and insulator. Install metal rod mechanism using special binder materials and insulator together , can with stand short-circuit current open the electric power. Moistureproof fuse has not blister, deformation, open ,large capacity, UV,long life, superior electric properties, dielectric strength and excellent mechanical stiffness and consecrated ability. The whole organization to neutral, convenient installation, safe and reliable. 1. The ambient temperature is not higher than +40 C, not lower than-40 C 2. The altitude does not exceed 3000m 3.The maximum wind speed does not exceed 35m/s 4. The earthquake intensity does not exceed 8 degrees1. Installation of drop fuse: (1) The melt should be tightened during installation (so that the melt is subjected to a tensile force of about 24.5N), otherwise it is easy to cause the contact to overheat. (2) The fuse installed on the cross arm (frame) should be firm and reliable, and there should be no shaking or shaking. (3) The melting tube should have a downward inclination angle of 25°±2°, so that the melting tube can quickly fall by its own weight when the melt is blown. (4) The fuse should be installed on the cross arm (frame) with a vertical distance of not less than 4m from the ground. If it is installed above the distribution transformer, it should maintain a horizontal distance of more than 0.5m from the outer contour boundary of the distribution transformer. A fall of a melting tube caused other accidents. (5) The length of the fuse tube should be adjusted moderately. It is required that the duckbill tongue can hold more than two-thirds of the length of the contact after closing, so as to avoid the misoperation of self-falling during operation, and the fuse tube should not hit the duckbill. , in order to prevent the melting tube from falling in time after the melt is blown. (6) The melt used must be a standard product of a regular manufacturer, and has a certain mechanical strength. Generally, the melt is required to withstand a tensile force of more than 147N. (7) The 10kV drop-out fuse is installed outdoors, and the distance between phases is required to be greater than 70cm. Second, the operation of the drop fuse: Under normal circumstances, it is not allowed to operate the drop fuse with load, only it is allowed to operate the no-load equipment (line). However, branch lines of 10kV distribution lines in rural power grids and distribution transformers with rated capacity less than 200kVA are allowed to operate with load according to the following requirements: (1) The operation shall be carried out by two persons (one to monitor and one to operate), but must wear qualified insulating gloves, insulating boots, and goggles, and operate with qualified insulating rods with matching voltage levels. Operation is prohibited in heavy rain. (2) During the operation of the gate, it is generally stipulated that the middle phase is pulled first, then the leeward side phase is pulled, and then the windward side phase is pulled. This is because the distribution transformer is changed from three-phase operation to two-phase operation, and the arc spark generated when the intermediate phase is broken is small, which will not cause a short circuit between phases. The second is to break the leeward side phase, because the middle phase has been pulled apart, and the distance between the leeward side phase and the windward side phase has doubled. Even if there is an overvoltage, the possibility of short circuit between phases is very small. When the windward side phase is pulled back, there is only a capacitive current to the ground, and the spark generated is very slight. (3) When closing, the operation sequence is reversed when closing, first close the windward side phase, then close the leeward side phase, and then close the middle phase. (4) Operating the melting tube is a frequent item. If you don’t pay attention, it will cause the contact to burn and cause poor contact, overheat the contact, and anneal the spring, which will make the contact worse and form a vicious circle. Therefore, when pulling and closing the fusion tube, use moderate force. After closing, carefully check that the duckbill tongue can be tightly buckled for more than two-thirds of the length of the tongue. You can use the brake lever to hook the upper duckbill and press down a few times. Try pulling again to check if it fits properly. When the switch is closed, it is not in place or not firmly closed, and the static contact pressure on the fuse is insufficient, which can easily cause the contact to burn or the fuse tube to fall by itself.

Hot Products

DL  16-800mm² 8.4-21mm  Aluminium Connecting Terminal   Cable Lug  Electric power fitting

DL 16-800mm² 8.4-21mm Aluminium Connecting Terminal Cable Lug Electric power fitting

FBCZ  5.5-55KW  380-1140V  Mine and tunnel flameproof type ground draw out type ventilator fan

FBCZ 5.5-55KW 380-1140V Mine and tunnel flameproof type ground draw out type ventilator fan

GHK  200-400A  1140V  Mine low pressure vacuum explosion-proof isolation reversing switch

GHK 200-400A 1140V Mine low pressure vacuum explosion-proof isolation reversing switch

DTG  4-1000mm²  4.2-23mm Tube Pressed Copper connecting Terminal  Tinned Copper Cable Lug

DTG 4-1000mm² 4.2-23mm Tube Pressed Copper connecting Terminal Tinned Copper Cable Lug

VV/VLV  0.6/1KV  1.5-800mm²  1-5cores   PVC insulation and sheathed power cable

VV/VLV 0.6/1KV 1.5-800mm² 1-5cores PVC insulation and sheathed power cable

YJLV22 0.6/1KV 2-5 cores 16-400mm² Armored buried aluminum core power cable

YJLV22 0.6/1KV 2-5 cores 16-400mm² Armored buried aluminum core power cable

PA series   1KV  4-120mm²   Overhead cable fixed insulation plastic tensioning clamp

PA series 1KV 4-120mm² Overhead cable fixed insulation plastic tensioning clamp

BS-JKLYJ 0.6/1KV  16-120mm 2-4 core Outdoor Aluminium core connected parallel overhead insulated cables

BS-JKLYJ 0.6/1KV 16-120mm 2-4 core Outdoor Aluminium core connected parallel overhead insulated cables

DTK  25-240mm²  7-21mm  Quick connect energy-saving electrical connector

DTK 25-240mm² 7-21mm Quick connect energy-saving electrical connector

SCB 11KV 15KV 33KV 630-3150KVA three-phase dry-type transformer

SCB 11KV 15KV 33KV 630-3150KVA three-phase dry-type transformer