TSJA 50-2000KVA 380V 0-650V Three-phase oil-immersed self-cooling induction voltage regulator

Shop online for TSJA 50-2000KVA 380V 0-650V three-phase oil-immersed self-cooling induction voltage regulator. We are a factory offering quality products.

Request a Quote
  • TSJA 50-2000KVA 380V 0-650V Three-phase oil-immersed self-cooling induction voltage regulator
  • TSJA 50-2000KVA 380V 0-650V Three-phase oil-immersed self-cooling induction voltage regulator
  • TSJA 50-2000KVA 380V 0-650V Three-phase oil-immersed self-cooling induction voltage regulator
  • TSJA 50-2000KVA 380V 0-650V Three-phase oil-immersed self-cooling induction voltage regulator
  • TSJA 50-2000KVA 380V 0-650V Three-phase oil-immersed self-cooling induction voltage regulator
  • TSJA 50-2000KVA 380V 0-650V Three-phase oil-immersed self-cooling induction voltage regulator
  • TSJA 50-2000KVA 380V 0-650V Three-phase oil-immersed self-cooling induction voltage regulator
  • TSJA 50-2000KVA 380V 0-650V Three-phase oil-immersed self-cooling induction voltage regulator
  • TSJA 50-2000KVA 380V 0-650V Three-phase oil-immersed self-cooling induction voltage regulator
  • TSJA 50-2000KVA 380V 0-650V Three-phase oil-immersed self-cooling induction voltage regulator
  • TSJA 50-2000KVA 380V 0-650V Three-phase oil-immersed self-cooling induction voltage regulator

PRODUCTS DETAILS

The induction voltage regulator can adjust the output voltage steplessly, smoothly and continuously under load conditions. It is mainly used for electrical and electrical testing, electric furnace temperature control, rectification equipment matching, generator excitation, etc. It is widely used in machinery manufacturing, chemical industry, textile, communication, military and other industries. TDJA, TSJA oil-immersed voltage regulators adopt new chute technology, with good waveform, which meets the requirements of IEC standard for electrical test power supply. This series of products can adjust the load voltage smoothly and steplessly, with small distortion of output voltage waveform and long life. , Reliable operation, convenient use and maintenance, low loss, strong overload capacity, with two voltage regulation speeds, it is an ideal adjustable power supply for motors, transformers and other electrical appliances.1. Product Name: Induction Voltage Regulator 2. Product model number: TSJA- 3. Rated capacity: 30KVA-1000kVA 4. Number of phases: three-phase 5. Frequency: 50Hz-60HZ 6. Rated input voltage: AC 380V 7. Output voltage range: AC 0-420V 0-630V 0-760V0-500V 0-430V 0-1200V can be customized according to requirements 8. Starting voltage: not greater than the value (5V) 9. Rated output current: rated A 10. Cooling method: oil immersion self-cooling 11. Insulation class: Class A 12. Wiring method: Y 13. Electrical method: induction auto coupling 14. Working mode: long-term continuous operation 15. Voltage regulation mode: electric, manual 16. Three-phase asymmetry: Under the condition that the three-phase input voltage is symmetrical and the rated value, the asymmetry of the three-phase no-load output voltage value of the voltage regulator is less than or equal to 1% 17. Voltage regulation time: ≤1.5min 18. Noise: <80dB 19. Dimensions: / Diameter 1550mm, Height 2150mm 20. Weight: /2600kg 参数1 参数2 参数3 参数4 参数5 参数6 规格_看图王(1) 接线 外形 形象31. Non-contact adjustment, long service life; 2. Applicable to loads of various natures; 3. Strong overload capacity; 4 .Reliable operation, easy to use and maintain Environmental conditions: 1. Altitude: ≤1000M 2. Ambient temperature: -10~+40℃ 3. Relative humidity: the average relative humidity of the year and month is not more than 90% 4. Use environment: indoor 5. The installation site is well ventilated, without serious vibration and turbulence, and without gas, steam, dust, dirt, chemical deposits and other explosive and corrosive media that seriously affect the insulation of the regulator.Selection: 1. The user's voltage situation The user is required to detect the no-load voltage value and the load voltage value. 2. The distance between the transformer and the electrical equipment The user needs to measure the distance between the user's transformer and its electrical equipment. 3. The user's cable situation The user needs to check the situation of the cable used by himself. Generally, it is necessary to match the total power of the equipment. 4. The total power of the starting equipment The user should check the total power of the equipment used by himself. According to the above information, the user can choose the corresponding model product or propose customization. Ordering instructions: When ordering, the product model, capacity, rated output voltage, rated input voltage, power input and output position, etc. should be stated; If there is a special request, it must be explained in detail, and the consumption can be designed according to the user's request;

Hot Products

ZR-YJV 8.7/35KV 25-1200mm² 1-3 core  Medium and high voltage flame retardant cross-linked copper core power cable

ZR-YJV 8.7/35KV 25-1200mm² 1-3 core Medium and high voltage flame retardant cross-linked copper core power cable

HRW 12/35KV Outdoor high voltage protection AC drop-out fuse

HRW 12/35KV Outdoor high voltage protection AC drop-out fuse

GTY  1.5-1000mm²  1.8-44mm  Tinned copper connecting tube  cable lugs

GTY 1.5-1000mm² 1.8-44mm Tinned copper connecting tube cable lugs

JLSZY-10KV 5-1000A 10VA Outdoor three-phase four-wire combined transformer high voltage power metering box

JLSZY-10KV 5-1000A 10VA Outdoor three-phase four-wire combined transformer high voltage power metering box

FBCZ  5.5-55KW  380-1140V  Mine and tunnel flameproof type ground draw out type ventilator fan

FBCZ 5.5-55KW 380-1140V Mine and tunnel flameproof type ground draw out type ventilator fan

MGF  45-250mm  Substation fitting Dead-end caps (Damper type) Electric power fittings

MGF 45-250mm Substation fitting Dead-end caps (Damper type) Electric power fittings

DSQ/SSQ/ZT 10/35KV 1-5 Cores 10-500mm² Heat Shrink Cable Rain Skirt and Heat Shrink Cable Finger Cover Cable Termination Accessories

DSQ/SSQ/ZT 10/35KV 1-5 Cores 10-500mm² Heat Shrink Cable Rain Skirt and Heat Shrink Cable Finger Cover Cable Termination Accessories

MJP(B、T、TN)   0.6/1KV  5.2-26.5mm   Pre-insulated connecting sleeve for indoor and outdoor cables

MJP(B、T、TN) 0.6/1KV 5.2-26.5mm Pre-insulated connecting sleeve for indoor and outdoor cables

SVR 6-35KV 630-20000KVA Outdoor three-phase high voltage line feed automatic voltage regulator

SVR 6-35KV 630-20000KVA Outdoor three-phase high voltage line feed automatic voltage regulator

DGS/DJS  5-24W  127V  Mine Flameproof type safety emergency indicator light

DGS/DJS 5-24W 127V Mine Flameproof type safety emergency indicator light

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours