XRNT 6KV 12KV 20KV 24KV 35KV 40.5KV 50KA High voltage current limiting fuses for protection of transformers

Introducing XRNT series high voltage current limiting fuses for transformer protection. As a factory, we offer reliable and durable solutions. Shop now!

Request a Quote
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers

PRODUCTS DETAILS

It can be used in indoor system of 50HZ and rated voltage of 3.6KV, 7.2KV, 12KV, 24KV, 40.5KV used together with other switch facilities such as loading switches, vacuum contractors, it can protect electric transformers and other electric facilities against overloading or circuit break. it is also a necessary accessory for high-voltage switch.High voltage current limiting fuseHigh breaking capacity: The rated breaking current of the product is 40KA~50KA. Low power loss: ensures a low temperature rise of the product, which is more advantageous when fuses are used in fully enclosed insulation devices. Low arc voltage: During the breaking process, the arc voltage is low, and when used in systems below the rated voltage, the arc voltage will further decrease, which can be used for 12KV or 7 There is no danger of damaging the insulation of the 2KV system. Small characteristic curve error: The error of the time current characteristic curve is less than ± 10%, ensuring the reliability of the product. Standardization of specifications: The rated parameters of the product comply with the International Electrotechnical Commission (IEC) standards R10 and R20 series. There are two types of wiring: (1) Busbar type, with overall dimensions in accordance with British (BS) standards; (2) , plug-in, with external dimensions in accordance with German (DIN) standards; Moreover, they all comply with the International Electrotechnical Commission (IEC) standards. The busbar type can be directly fastened to the busbar with screws, which has the advantages of small installation volume and reliable contact; The plug-in type is easy to replace and can be operated with power. Can be equipped with an impactor: Tungsten wires in parallel with the melt can melt within a few thousandths of a second at the beginning of the arc, igniting the powder device. The firing pin operated by a small amount of gunpowder immediately acts and provides a signal with sufficient energy, or causes other electrical appliances to act, or provides interlocking. The output energy of the fuse impactor that meets the British (BS) standard is (1-3) joules, while the output energy of the fuse impactor that meets the German (DIN) standard is (2-5) joules.

Hot Products

HRW/HRXWO   10-35KV  10A   Outdoor pollution resistant type silicon rubber high voltage current limiting fuse

HRW/HRXWO 10-35KV 10A Outdoor pollution resistant type silicon rubber high voltage current limiting fuse

HY5WBG  outdoor 10kv line pillar zinc oxide arrester with bracket no gap discharge

HY5WBG outdoor 10kv line pillar zinc oxide arrester with bracket no gap discharge

BJX  220/380V  10-400A   Explosion proof anti-corrosion junction box

BJX 220/380V 10-400A Explosion proof anti-corrosion junction box

FZRN25-12D 12KV 630A Indoor high-voltage vacuum load switch and fuse combination electrical appliances

FZRN25-12D 12KV 630A Indoor high-voltage vacuum load switch and fuse combination electrical appliances

JCD 16-300mm² 1.5-70mm² 150-270A  Electric meter box into the household wire clip

JCD 16-300mm² 1.5-70mm² 150-270A Electric meter box into the household wire clip

CKSG 10-60Kvar 11-77A Three-phase series filter reactor

CKSG 10-60Kvar 11-77A Three-phase series filter reactor

LW8-40.5KV 2000A Outdoor high voltage three-phase AC SF6 circuit breaker

LW8-40.5KV 2000A Outdoor high voltage three-phase AC SF6 circuit breaker

FHJDC 10KV Overhead Wire Lightning Protection Ground Clamp

FHJDC 10KV Overhead Wire Lightning Protection Ground Clamp

SG 100-3600KVA 380-3300V three-phase tunnel special booster dry-type transformer

SG 100-3600KVA 380-3300V three-phase tunnel special booster dry-type transformer

MRJ  120-400mm²  19-33mm  Spacers for double bus-bar conductor  Electric power protective fitting

MRJ 120-400mm² 19-33mm Spacers for double bus-bar conductor Electric power protective fitting

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours