YBF-35/0.4KV 630-2500KVA special box-type substation for photovoltaic wind power station

Shop a YBF-35/0.4KV 630-2500KVA box-type substation for photovoltaic wind power stations at our factory. Ensure reliable energy distribution and maximize efficiency. Order now!

Request a Quote
  • YBF-35/0.4KV 630-2500KVA special box-type substation for photovoltaic wind power station
  • YBF-35/0.4KV 630-2500KVA special box-type substation for photovoltaic wind power station
  • YBF-35/0.4KV 630-2500KVA special box-type substation for photovoltaic wind power station
  • YBF-35/0.4KV 630-2500KVA special box-type substation for photovoltaic wind power station
  • YBF-35/0.4KV 630-2500KVA special box-type substation for photovoltaic wind power station
  • YBF-35/0.4KV 630-2500KVA special box-type substation for photovoltaic wind power station

PRODUCTS DETAILS

YBF-35 series box-type substation for photovoltaic wind power station is a special equipment for grid-connected output after raising the voltage of 0.6-0.69KV from wind turbine to 35KV. This product is a new product developed by our company in response to the requirements of offshore wind farms and photovoltaic power plants with large capacity and high protection.参数1 参数2 参数3 结构2 外形尺寸1. The box shell is designed according to the actual situation with reference to foreign advanced technology, and it has the characteristics of firmness, heat insulation and ventilation, stable performance, corrosion prevention, dust prevention, waterproof, small animal prevention, beautiful appearance, etc. There are many choices of shell materials, such as steel plate, composite plate, stainless steel plate, cement plate, etc. 2. There are high-voltage switchgear such as xgn15, hxgn17 or kyn28a and other equipment in the high-voltage room for high-voltage incoming line, high-voltage metering and high-voltage outgoing line. The high-voltage side can be arranged with ring network power supply, terminal power supply, dual power supply and other power supply modes, and high-voltage metering elements can also be installed to meet the requirements of high-voltage metering. The main switch is generally load switch or vacuum circuit breaker, with compact and reasonable structure and perfect anti misoperation function. 3. There are low-voltage switchgear such as GGD, GCS or MNS and other equipment in the low-voltage room for low-voltage incoming line, reactive compensation and low-voltage outgoing line. The low-voltage side adopts the panel type or cabinet mounted structure to form the power supply scheme required by the user, which can meet the power distribution, lighting distribution, reactive compensation, electric energy metering and other functions. The main switch generally adopts the universal circuit breaker or the intelligent circuit breaker, which is flexible in installation and simple in operation. 4. The transformer in the transformer room can use the fully sealed oil immersed transformer or dry-type transformer. The oil immersed transformer can be S9, S11, S13 or SH15, and the dry-type transformer can be scb10, scb11, SGB10 or scbh15. According to the actual needs of customers, it can be configured freely, which has the advantages of more selectivity and flexibility. 5. The cover of the box is designed with double-layer structure, and the interlayer is filled with foam plastics, which has good heat insulation function. The transformer room is equipped with anti condensation and automatic temperature control monitoring, heating and cooling devices. A dust-proof device is arranged on the position of the door sheet and the louver outside the side plate.1. Ambient air temperature: -5~+40 and the average temperature should not exceed +35 in 24h. 2. Install and use indoors. Altitude above sea level for operation site should not exceed 2000M. 3. Relative humidity should not exceed 50% at max temperature +40. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20. But in view of the temperature change, it is possible that moderate dews will produce casually. 4. Installation gradient not exceed 5. 5. Install in the places without fierce vibration and shock and the sites insufficient to erode the electrical components. 6. Any specific requirement, consult with manufactory.

Hot Products

KYN28 24KV 630A 2000A 4000A Armoured removable AC enclosed switchgear

KYN28 24KV 630A 2000A 4000A Armoured removable AC enclosed switchgear

RW11 series 12KV 100/200A outdoor high voltage protection switch drop-out fuse

RW11 series 12KV 100/200A outdoor high voltage protection switch drop-out fuse

SBT  12-20mm  Electric power fittings and equipment terminal clamp  Copper transformer wire clip

SBT 12-20mm Electric power fittings and equipment terminal clamp Copper transformer wire clip

NLL 5-46.5mm 40-120KN 10KV Overhead Insulated Conductor Fittings Bolt Type Tension Clamp

NLL 5-46.5mm 40-120KN 10KV Overhead Insulated Conductor Fittings Bolt Type Tension Clamp

YFFB  300/500V  0.5-25mm²  2-60 cores   Elevator drag chain accompanying flexible cable

YFFB 300/500V 0.5-25mm² 2-60 cores Elevator drag chain accompanying flexible cable

JH 16-240mm² 4.8-22.5mm H-type parallel groove wire clamp branch type cable crimping wire clamp

JH 16-240mm² 4.8-22.5mm H-type parallel groove wire clamp branch type cable crimping wire clamp

ZN12-40.5KV 1250-2000A  Indoor high voltage vacuum circuit breaker handcart

ZN12-40.5KV 1250-2000A Indoor high voltage vacuum circuit breaker handcart

FD/FF/FR/FDZ   35-630mm²   Overhead conductor damping device  Power  fittings dampers

FD/FF/FR/FDZ 35-630mm² Overhead conductor damping device Power fittings dampers

GKD  380/660/1140V  50-3200A  Low voltage switchgear for mining   Incoming and outgoing cabinet

GKD 380/660/1140V 50-3200A Low voltage switchgear for mining Incoming and outgoing cabinet

ZW43-12G 12KV 630A Outdoor High Voltage Vacuum Circuit Breaker Switchgear

ZW43-12G 12KV 630A Outdoor High Voltage Vacuum Circuit Breaker Switchgear

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours